Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC
GB/T 12706.1-2020
Spec |
Conductor diameter mm |
Approx outer diameter of cable mm |
Approx cable weight kg/km |
||||||
|
|
NH |
ZAN |
ZBN |
ZCN |
NH |
ZAN |
ZBN |
ZCN |
3×16 |
5.0 |
18.9 |
192 |
192 |
19.2 |
659.4 |
713.1 |
719.2 |
680.1 |
3×25 |
6.1 |
22.5 |
22.5 |
22.5 |
22.5 |
974.7 |
1044.6 |
1051.8 |
996.1 |
3×35 |
72 |
24.8 |
24.8 |
24.8 |
24.8 |
1274.1 |
1361.6 |
1369.6 |
1300.0 |
3×50 |
8.4 |
27.9 |
28.3 |
27.9 |
27.9 |
1659.7 |
1806.0 |
1775.4 |
1692.0 |
3×70 |
10.0 |
32.0 |
32.4 |
32.0 |
32.0 |
2320.7 |
2510.1 |
2474.6 |
2362.4 |
3×95 |
12.0 |
36.4 |
36.9 |
36.4 |
36.4 |
3132.4 |
3375.7 |
3334.7 |
3185.7 |
3×120 |
12.2 |
37.5 |
37.9 |
37.5 |
37.5 |
3797.7 |
4053.5 |
4010.8 |
3853.6 |
3×150 |
13.6 |
41.8 |
41.8 |
41.8 |
41.8 |
4681.2 |
4957.1 |
49455 |
4749.1 |
3×185 |
15.2 |
46.3 |
46.3 |
46.3 |
46.3 |
5813.6 |
6154.0 |
6133.9 |
5896.1 |
3×240 |
17.4 |
51.9 |
51.9 |
51.9 |
51.9 |
7519.6 |
7947.6 |
7923.0 |
7621.7 |
3×300 |
19.5 |
572 |
57.2 |
57.2 |
57.2 |
9355.8 |
9847.1 |
9847.1 |
9478.3 |
3×400 |
22.0 |
64.0 |
64.0 |
64.0 |
64.0 |
11858.3 |
12473.0 |
12473.0 |
12009.4 |
4×1.5 |
1.39 |
12.0 |
12.3 |
12.3 |
12.3 |
186.2 |
201.4 |
201.4 |
201.4 |
4×2.5 |
1.76 |
12.9 |
13.2 |
13.2 |
12.9 |
236.7 |
252.8 |
252.8 |
241.3 |
4×4 |
2.22 |
14.0 |
14.3 |
14.3 |
14.0 |
3092 |
327.2 |
327.2 |
314.2 |
4×6 |
2.74 |
15.3 |
15.6 |
15.6 |
15.3 |
402.2 |
422.6 |
422.6 |
407.8 |
4×10 |
4.0 |
18.3 |
18.6 |
18.6 |
18.6 |
588.5 |
634.7 |
640.6 |
607.4 |
4×16 |
5.0 |
21.0 |
21.0 |
21.0 |
21.0 |
845.5 |
900.0 |
906.7 |
863.1 |
4×25 |
6.1 |
24.7 |
24.7 |
24.7 |
24.7 |
1250.8 |
1328.7 |
1336.6 |
1274.7 |
4×35 |
72 |
27.4 |
27.4 |
27.4 |
27.4 |
1643.6 |
1741.3 |
1750.2 |
1672.6 |
4×50 |
8.4 |
30.9 |
31.4 |
30.9 |
30.9 |
2163.3 |
2326.9 |
2292.5 |
2199.4 |
4×70 |
10.0 |
35.5 |
35.9 |
35.5 |
35.5 |
3031.9 |
3243.8 |
3203.9 |
3078.4 |
4×95 |
12.0 |
40.5 |
41.0 |
40.5 |
40.5 |
4098.6 |
4370.6 |
4324.5 |
4158.1 |
4×120 |
12.2 |
41.8 |
42.3 |
41.8 |
41.8 |
4998.3 |
5285.4 |
5236.4 |
5060.6 |
4×150 |
13.6 |
46.4 |
46.4 |
46.4 |
46.4 |
6136.1 |
6444.3 |
6430.9 |
6211.8 |
4×185 |
15.2 |
51.6 |
51.6 |
51.6 |
51.6 |
7649.6 |
8031.2 |
8006.8 |
7741.8 |
4×240 |
17.4 |
57.8 |
57.8 |
57.8 |
57.8 |
9896.6 |
10376.0 |
10346.5 |
10010.5 |
4×300 |
19.5 |
63.7 |
63.7 |
63.7 |
63.7 |
12314.4 |
12861.8 |
12861.8 |
12451.0 |
4×400 |
22.0 |
71.3 |
71.3 |
71.3 |
71.3 |
15606.1 |
16291.7 |
16291.7 |
15774.6 |
5×1.5 |
1.39 |
13.0 |
13.3 |
13.3 |
13.3 |
218.6 |
235.5 |
235.5 |
235.5 |
5×2.5 |
1.76 |
14.0 |
14.3 |
14.3 |
14.0 |
280.8 |
298.8 |
299.5 |
285.8 |
5×4 |
2.22 |
152 |
15.5 |
15.5 |
15.2 |
369.9 |
391.0 |
391.0 |
375.4 |
5×6 |
2.74 |
16.6 |
16.9 |
16.9 |
16.6 |
484.6 |
508.5 |
508.5 |
490.7 |
5×10 |
4.0 |
20.4 |
20.4 |
20.4 |
20.4 |
7192 |
769.4 |
776.9 |
7356 |
5×16 |
5.0 |
23.1 |
23.1 |
23.1 |
23.1 |
1031.4 |
1097.7 |
1106.4 |
1052.2 |
5×25 |
6.1 |
27.2 |
27.2 |
27.2 |
27.2 |
1533.7 |
1628.8 |
1637.6 |
1562.1 |
5×35 |
72 |
30.1 |
30.1 |
30.1 |
30.1 |
2021.3 |
2140.4 |
2150.2 |
2055.8 |
5×50 |
8.4 |
34.2 |
34.7 |
34.2 |
34.2 |
2680.5 |
2876.9 |
2838.3 |
2723.7 |
5×70 |
10.0 |
39.3 |
39.8 |
39.3 |
39.3 |
3760.0 |
4014.9 |
3970.1 |
3815.8 |
5×95 |
12.0 |
45.1 |
45.5 |
45.1 |
45.1 |
5107.2 |
5436.4 |
5383.7 |
5178.7 |
5×120 |
12.2 |
46.3 |
46.7 |
46.3 |
46.3 |
6204.7 |
6550.6 |
6495.8 |
6279.6 |
5×150 |
13.6 |
51.6 |
51.6 |
51.6 |
51.6 |
7643.2 |
8020.9 |
8004.6 |
7734.5 |
5×185 |
15.2 |
57.4 |
57.4 |
57.4 |
57.4 |
9525.2 |
9992.5 |
9963.3 |
9636.4 |
5×240 |
17.4 |
64.2 |
64.2 |
64.2 |
64.2 |
12322.0 |
12909.5 |
12874.3 |
12459.9 |
Q: What makes XLPE insulation ideal for fire-resistant cables?
A: XLPE (Cross-Linked Polyethylene) offers high thermal stability (up to 90°C) and halogen-free properties, ensuring minimal smoke and toxic gas emission during fires.
Q: Which fire standards does this cable comply with?
A: Typically meets IEC 60331-21 (fire survival for 90/120 mins) and IEC 60332-1/3 (flame retardancy), with optional UL/BS certifications for regional markets.
Q: Where are XLPE fire cables commonly used?
A: Critical installations like hospitals, tunnels, data centers, and industrial plants where circuit integrity during fires is mandatory.
Q: Can these cables operate in high-temperature environments?
A: Yes, XLPE withstands temperatures up to 90°C continuously, with short-term overload tolerance as per IEC 60502.
Q: Is XLPE fire-resistant cable suitable for outdoor use?
A: Absolutely, with UV-resistant outer sheath options available for prolonged sunlight exposure.
Q: How does XLPE compare to PVC in fire scenarios?
A: XLPE produces less smoke and corrosive gases, making it safer for confined spaces compared to traditional PVC insulation.
Q: What voltage ratings are available for this cable type?
A: Common ratings include 0.6/1kV (low-voltage) and 3.6/6kV (medium-voltage), customized per project needs.
Q: Does XLPE fire cable require special installation practices?
A: Standard wiring methods apply, but bending radius should adhere to manufacturer guidelines to avoid insulation damage.
Q: Can these cables be used in explosive atmospheres?
A: Yes, when combined with flameproof conduit or certified as per IEC 60079 standards for hazardous zones.
Q: What maintenance is needed for XLPE fire-resistant cables?
A: Minimal maintenance; periodic inspections for insulation integrity and terminations are recommended.
Контактное лицо: Mr. Bai
Телефон: +8619829885532