logo
Главная страница ПродукцияXLPE изолировало силовой кабель

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC
Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC

Большие изображения :  Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC

Подробная информация о продукте:
Place of Origin: Hebei,China
Фирменное наименование: Zhongdong
Сертификация: ISO9001, CE, CCC, RoHS, VDE, cUL, CSA
Оплата и доставка Условия:
Minimum Order Quantity: To be negotiated
Цена: To be negotiated
Packaging Details: Rolls, Wooden Drums, Steel Drums, Reels or customized
Delivery Time: 7-30 days based on different qty
Payment Terms: ,L/C,T/T
Supply Ability: 100KM/Week

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC

описание
Insulation: XLPE HPDE Voltage: 12/20kV
Conductor Material: Aluminium Alloy Conductor Application: Overhead or Underground,Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying
Shield: Copper wire or Copper Tape No of Core: Single Core
Выделить:

Fire resistant XLPE power cable

,

12/20kV single core cable

,

XLPE insulated high voltage cable

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC



APPLICATION

  • The cable is a ‌fire-resistant, ‌XLPE-insulated, and ‌PVC-sheathed power cable rated for voltages up to ‌0.6/1 kV‌. It is widely used in:
  • Power Distribution Systems‌ – Suitable for fixed installations in buildings, industrial plants, and infrastructure projects, delivering reliable power transmission in low-voltage networks.
  • Fire Safety Critical Areas‌ – The ‌"N" (fire-resistant)‌ feature ensures continued operation during fires, making it ideal for emergency circuits, evacuation routes, and fire protection systems.
  • Industrial & Commercial Buildings‌ – Commonly deployed in wiring systems for machinery, lighting, and HVAC systems where flame retardancy and high thermal resistance are requiredSubstations & Switchgear‌ – Used in control panels and secondary distribution networks due to its stability under voltage fluctuations.
  • Public Infrastructure‌ – Applied in tunnels, metro systems, and hospitals where fire safety and long-term durability are essential.


CONSTRUCTION


  • Conductor:Class 1/Class 2 stranded Copper conductor 
  • Refractory layer: Single sided gold mica tape 
  • Insulation: XLPE  
  • Filler(options):Polypropylene mesh tear rope or flame-retardant filling 
  • Outer sheath:Polyvinyl chloride (PVC)

Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 0Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 1

CHARACTERISTICS

  • Maximum operating temperature of conductor:+90℃
  • Operating ambient temperature: -15℃~+55℃
  • Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.) 
  • Minimum Bending Radius:   Single core:20multi core:15D   (D is the actual outer diameter of the cable)


STANDARD


GB/T 12706.1-2020




SPECIFICATIONS


Spec
mm²

Conductor diameter              mm

Approx outer diameter of cable    

mm

Approx cable weight

 kg/km

 

 

NH

ZAN

ZBN

ZCN

NH

ZAN

ZBN

ZCN

3×16

5.0

18.9

192

192

19.2

659.4

713.1

719.2

680.1

3×25

6.1

22.5

22.5

22.5

22.5

974.7

1044.6

1051.8

996.1

3×35

72

24.8

24.8

24.8

24.8

1274.1

1361.6

1369.6

1300.0

3×50

8.4

27.9

28.3

27.9

27.9

1659.7

1806.0

1775.4

1692.0

3×70

10.0

32.0

32.4

32.0

32.0

2320.7

2510.1

2474.6

2362.4

3×95

12.0

36.4

36.9

36.4

36.4

3132.4

3375.7

3334.7

3185.7

3×120

12.2

37.5

37.9

37.5

37.5

3797.7

4053.5

4010.8

3853.6

3×150

13.6

41.8

41.8

41.8

41.8

4681.2

4957.1

49455

4749.1

3×185

15.2

46.3

46.3

46.3

46.3

5813.6

6154.0

6133.9

5896.1

3×240

17.4

51.9

51.9

51.9

51.9

7519.6

7947.6

7923.0

7621.7

3×300

19.5

572

57.2

57.2

57.2

9355.8

9847.1

9847.1

9478.3

3×400

22.0

64.0

64.0

64.0

64.0

11858.3

12473.0

12473.0

12009.4

4×1.5

1.39

12.0

12.3

12.3

12.3

186.2

201.4

201.4

201.4

4×2.5

1.76

12.9

13.2

13.2

12.9

236.7

252.8

252.8

241.3

4×4

2.22

14.0

14.3

14.3

14.0

3092

327.2

327.2

314.2

4×6

2.74

15.3

15.6

15.6

15.3

402.2

422.6

422.6

407.8

4×10

4.0

18.3

18.6

18.6

18.6

588.5

634.7

640.6

607.4

4×16

5.0

21.0

21.0

21.0

21.0

845.5

900.0

906.7

863.1

4×25

6.1

24.7

24.7

24.7

24.7

1250.8

1328.7

1336.6

1274.7

4×35

72

27.4

27.4

27.4

27.4

1643.6

1741.3

1750.2

1672.6

4×50

8.4

30.9

31.4

30.9

30.9

2163.3

2326.9

2292.5

2199.4

4×70

10.0

35.5

35.9

35.5

35.5

3031.9

3243.8

3203.9

3078.4

4×95

12.0

40.5

41.0

40.5

40.5

4098.6

4370.6

4324.5

4158.1

4×120

12.2

41.8

42.3

41.8

41.8

4998.3

5285.4

5236.4

5060.6

4×150

13.6

46.4

46.4

46.4

46.4

6136.1

6444.3

6430.9

6211.8

4×185

15.2

51.6

51.6

51.6

51.6

7649.6

8031.2

8006.8

7741.8

4×240

17.4

57.8

57.8

57.8

57.8

9896.6

10376.0

10346.5

10010.5

4×300

19.5

63.7

63.7

63.7

63.7

12314.4

12861.8

12861.8

12451.0

4×400

22.0

71.3

71.3

71.3

71.3

15606.1

16291.7

16291.7

15774.6

5×1.5

1.39

13.0

13.3

13.3

13.3

218.6

235.5

235.5

235.5

5×2.5

1.76

14.0

14.3

14.3

14.0

280.8

298.8

299.5

285.8

5×4

2.22

152

15.5

15.5

15.2

369.9

391.0

391.0

375.4

5×6

2.74

16.6

16.9

16.9

16.6

484.6

508.5

508.5

490.7

5×10

4.0

20.4

20.4

20.4

20.4

7192

769.4

776.9

7356

5×16

5.0

23.1

23.1

23.1

23.1

1031.4

1097.7

1106.4

1052.2

5×25

6.1

27.2

27.2

27.2

27.2

1533.7

1628.8

1637.6

1562.1

5×35

72

30.1

30.1

30.1

30.1

2021.3

2140.4

2150.2

2055.8

5×50

8.4

34.2

34.7

34.2

34.2

2680.5

2876.9

2838.3

2723.7

5×70

10.0

39.3

39.8

39.3

39.3

3760.0

4014.9

3970.1

3815.8

5×95

12.0

45.1

45.5

45.1

45.1

5107.2

5436.4

5383.7

5178.7

5×120

12.2

46.3

46.7

46.3

46.3

6204.7

6550.6

6495.8

6279.6

5×150

13.6

51.6

51.6

51.6

51.6

7643.2

8020.9

8004.6

7734.5

5×185

15.2

57.4

57.4

57.4

57.4

9525.2

9992.5

9963.3

9636.4

5×240

17.4

64.2

64.2

64.2

64.2

12322.0

12909.5

12874.3

12459.9




OUR FACTORY


Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 2


APPLICATION


Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 3Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 4Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 5

PARTNERS


Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 6Fire Resistant XLPE Insulated Power Cable 1.5-800mm2 1-5 Core CU/XLPE/PVC 7


FAQ

Q: What makes XLPE insulation ideal for fire-resistant cables?
A: XLPE (Cross-Linked Polyethylene) offers high thermal stability (up to 90°C) and halogen-free properties, ensuring minimal smoke and toxic gas emission during fires.

Q: Which fire standards does this cable comply with?
A: Typically meets IEC 60331-21 (fire survival for 90/120 mins) and IEC 60332-1/3 (flame retardancy), with optional UL/BS certifications for regional markets.

Q: Where are XLPE fire cables commonly used?
A: Critical installations like hospitals, tunnels, data centers, and industrial plants where circuit integrity during fires is mandatory.

Q: Can these cables operate in high-temperature environments?
A: Yes, XLPE withstands temperatures up to 90°C continuously, with short-term overload tolerance as per IEC 60502.

Q: Is XLPE fire-resistant cable suitable for outdoor use?
A: Absolutely, with UV-resistant outer sheath options available for prolonged sunlight exposure.

Q: How does XLPE compare to PVC in fire scenarios?
A: XLPE produces less smoke and corrosive gases, making it safer for confined spaces compared to traditional PVC insulation.

Q: What voltage ratings are available for this cable type?
A: Common ratings include 0.6/1kV (low-voltage) and 3.6/6kV (medium-voltage), customized per project needs.

Q: Does XLPE fire cable require special installation practices?
A: Standard wiring methods apply, but bending radius should adhere to manufacturer guidelines to avoid insulation damage.

Q: Can these cables be used in explosive atmospheres?
A: Yes, when combined with flameproof conduit or certified as per IEC 60079 standards for hazardous zones.

Q: What maintenance is needed for XLPE fire-resistant cables?
A: Minimal maintenance; periodic inspections for insulation integrity and terminations are recommended.


Контактная информация
Zhongdong Cable Co., Ltd.

Контактное лицо: Mr. Bai

Телефон: +8619829885532

Оставьте вашу заявку (0 / 3000)

Другие продукты